Immediate effects of 2 different whole-body vibration frequencies on muscle peak torque and stiffness.
Abstract
OBJECTIVE: To examine the immediate effects of 2 vibration protocols with different vibration frequencies that yielded the same maximum acceleration (106.75ms(-2)) on muscle peak torque and stiffness of knee extensor and flexor. DESIGN: Randomized crossover study with repeated measures. SETTING: Laboratory setting. PARTICIPANTS: Recreationally active male adults (N=10). INTERVENTION: Participants performed 10 bouts of 60-second static half squats intermitted with a 60-second rest period between bouts on a platform with no vibration (control) and a vibration frequency of 26Hz or 40Hz. MAIN OUTCOME MEASURES: Concentric and eccentric peak torques of knee extensor and flexor were examined within 5 minutes before and after vibration by isokinetic test. Young’s modulus as an index of tissue stiffness was determined at quadriceps and hamstring pre- and postvibration by using an ultrasound indentation method. RESULTS: The 2-way repeated-measures analysis of variance indicated a significant interaction effect between vibration and vibration frequency for knee extensor concentric peak torque (P=.003). The vibration-induced changes of knee extensor concentric peak torque in vibration frequency of 26Hz (14.5Nm) and 40Hz (12.0Nm) were found to be significantly greater than that in controls (-29.4Nm) (P<.05). The change in eccentric peak torque of knee flexor after vibration tended to be greater in 26Hz of vibration frequency when compared with controls (26Hz of vibration frequency vs controls: 13.9+/-7.1 vs -11.4+/-5.3Nm, P=.08). No statistically significant differences were obtained in tissue stiffness in the quadriceps and hamstring with any of the conditions. CONCLUSIONS: Our data suggest that whole-body vibration at a frequency of 26Hz and 40Hz preclude the decline in concentric peak torque of knee extensor observed after 10 bouts of 60 seconds of static half squats. A change in muscle mechanical stiffness property as induced by whole-body vibration is not supported by our data.
Autor: Siu PM, Tam BT, Chow DH, Guo JY, Huang YP, Zheng YP, Wong SH
Organisation: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, China. htpsiu@inet.polyu.edu.hk
Jahr: 2010
- Arch Phys Med Rehabil
- 2010
- 91(10)
- 1608-15
- PMID: 20875522
Schlagworte: #GRFS110, 26Hz, 40Hz, isokinetic eccentric torque
GID: 3100
Erstellt am: 21.01.2013